AMC16Z-ZA Data Center Monitor Device
● Designed specifically for the power supply management of server in the data center
● A+B independent 2 channels three-phase inlet
● U, I, P, Q, S, PF, kWh, kvarh
● 2nd-63rd Harmonic
-
ASJ10-LD1A Residual Current Relay
● The measurement of A-type after-current;
● The streamer display of current percentage;
● The setting of rated residual action current;
● The setting of non-driving time of limitation;
● Two-pair relay output;
● Possessing the function of on-the-spot and long-distance testing and resetting. -
ASJ20-LD1A Residual Current Relay
● The measurement of A-type residual current;
● The streamer display of current percentage;
● The setting of rated residual action current;
● The setting of non-driving time of limitation;
● Two-pair relay output;
● Possessing the function of on-the-spot and long-distance testing and resetting. -
24 Channel Temperature Controller ARTM-24
● 24 PT100,NTC or PT1000measurement;
● 2 Alarm relays;
● DIN Rail 35mm
● Auxiliary power supply adapts with AC220V, DC220V, DC110V;
● 1 RS485 serial communication, Modbus-RTU; -
AM2SE Series Medium Current Protection Relays
AM2SE Protection Relays used for 10 kv voltage applications.
Used for the protection of Line,Feeder
Cut out: 150*68mm
-
AM3SE Series Medium Voltage Protection Relays
● A complete set of protection, related to the application;
● 5 current input, 3 voltage input, 11DI, 5DO;
● Auxiliary power supply adapts with AC 220V, DC 220V, DC 110V, AC 110V, DC 48V, DC 24V;
● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
● 1 GPS for GPS timing; -
AIM-T500 Insulation Monitoring Device for undergrounded system up to AC690V or DC800V
● AC, DC main circuits● AC/DC main circuits with directly connected DC components, such as rectifiers● Systems with switch-mode power supplies● Systems with high leakage capacitances -
ADL400/C 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Accuracy:Class 0.5
● Active pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: MID; CE; IEC -
ACR10R-D16TE Single Phase Energy Meter for Solar Inverters
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), Apparent kWh (positive and negative),U, I, P, Q, S, PF, F, etc.
● Accuracy: Class 0.5
● Rated current: 80A, 120A, 200A, 300A
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 220V(±20%)
● Rated current: 80A, 120A, 200A, 300A
● Power supply: AC85-265V, or DC100-350V; DC24V(±10%); DC48V(±10%)
● Standard & Certificate: CE, etc. -
Acrel ATE400 Wireless Temperature Monitoring Sensor for Cable/Busbar Temperature Monitoring
● Model: ATE400
● Wireless transmit,470MHz;
● Wireless transmission distance, 150 meters;
● CT powered,starting current ≥5A
● Widely temperature measuring range, -50℃~+125℃.
● Standard&Certificate: CE; -
AWT100-LWHW LoraWAN wireless communication terminal
● Upstream Methods: LoRaWan Frequency : ( LoRaWan EU868 MHz, LoRaWan AS923Mhz)
● Upstream Protocol: LoRaWan Protocol
● Downstream Methods: RS485 Interface
● Downstream Protocol: MODBUS-RTU● Support: Up to 20~25 Acrel Devices with RS485 (MODBUS-RTU)● Power Supply: 24Vdc (default); 85~265Vac/Vdc (via AWT100-POW Module)● Standard&Certificate: CE-RED; IEC; LVD; EMC -
AWT100 wireless communication terminal
● WiFi: WiFi communication terminal● 4G: 4G communication terminal● NB: NB-IoTcommunication terminal● Lora: LoRa communication terminal● CE: Ethernet communication terminal -
Acrel AMC16Z-ZA Data Center Monitoring Device
● Designed specifically for the power monitoring of data center
● Monitor A+B independent 2 channels of 3 phase incoming circuits
● Monitor U,I,P,Q,S,PF,EP,EQ,UN, neutral current, etc.
● Monitor 6 channels of passive switch input, 2 channels of switch output
● Monitor 2-31st harmonic
● 1 RS485(Modbus-RTU)
● Monitor temperature and humidity
● Monitor residual current
● Standard&Certificate: CE; IEC -
AIM-T300 Insulation Monitoring Device
● AC, DC main circuits● AC/DC main circuits with directly connected DC components, such as rectifiers● Systems with switch-mode power supplies