AMC72(L)-DV DC Voltage Meter
● Measure voltage in DC system● Local display● RS485(MODBUS-RTU)● Set parameters● DI/DO, Relay alarm output● Applications:DC panels, solar power, telecommunications base stations, and charging posts -
AMC72(L)-DI DC Current Meter
● Current in: 75mV(via shunt) 0-20mA,4-20mA(via hall sensor)
● Power supply:AC/DC85-265V
● Accuracy:class0.5
-
AGF-AE/D200 Inverter Monitoring Energy Meter
● Type: AGF-AE/D200● Single phase three wire● Rated voltage: AC 120V/208V,240V(88%~110%)● Rated current: AC 100A , 200A● Application: inverters in Australia, Europe, North America and other areas● DIN 35 mm -
BD 3 Phase Voltage Transducer
● Model:BD-3V3 / BD-4V3
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD-3P/4P 3 Phase Active Power Transducer
● Model: BD-3P/BD-4P
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
AHBC-LTA Closed-loop Hall current sensor
● Excellent accuracy
● Low temperature drift
● Wide frequency bandwidth
● Optimized response time -
Open Hall Current Sensor
● Rated current input:0-(50-5000)A
● Rated output: 5v / 4v / 4-20mA
● Aperture: 20mm/40mm/55mm/etc
● Power supply: ±15V / 12V / 24V
-
BA20-AI AC Current Transducer Measuring 0-200A
● Model: BA20-AI/I, BA20-AI/V
● Aperture: 20mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA10-AI AC Current Transducer Measuring 0-50A
● Model: BA10-AI/I, BA10-AI/V
● Aperture: 9.5mm
● Input: AC0-(8-50)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA Series AC Straight Through Current Transducer
● Model: BA05,BA10,BA20,BA50
● Aperture: 5mm,10mm,20mm,50mm
● Input: AC0-10A,AC0-50A,AC0-200A,AC0600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BA50-AI AC Current Transducer Measuring 0-600A
● Model: BA50-AI/I, BA50-AI/V
● Aperture: 50mm
● Input: AC0-(60-600)A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
BD-AV Single Phase AC Voltage Transducer
● Model:BD-AV
● AC current input:AC0-300V,0-500V
● Overload: 1.2 times of rated value
● Analog Output: DC0-5V/0-10V/0-20mA/4-20mA
● Power supply: AC85-265V/DC24V/DC48V -
BD series Electrical Power/Energy Transducer
● Model: BD-3E/BD-4E
● Input:1A/5A; 380V;3P3W,3P4W
● Analog Output: DC 0-5V/0-10V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: AC85-265V/DC24V/DC48V -
ADW210 Series Multi-Loop Power Meter
● Mearsure Up to 4 circuit 3 phase
● LCD display
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADW200 Series Multi Channel Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication) -
ADW210 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
AKH-0.66/TD-50III Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~800A AC● Primary Current Input: 20mA, 5A● Rated Frequency: 50~60Hz● Installtion: installed on busbar● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
AKH-0.66/TD-60 Series of Current Transformers
● Measurement: Alternating Current (AC)● Rated Voltage: 660V AC● Accuracy: Class 0.2● Primary Current Input: 300~1000A AC● Primary Current Input: 20mA, 50mA● Rated Frequency: 50~60Hz● Installtion: installed on wires● Loop Count: 1 Loop● Sandard&Certificate: GB 156-2017; UL● Ambient temperature: -30℃ ~90℃
-
ADL3000-E/C(DTSD1352-C) 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: CE; IEC -
ADL200/C Single Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measurement: Active kWh (positive and negative), reactive power, U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), Infrared communication
● Multi tariff
● Data Record: 3 months historical energy data frozen storage(optional)
● Accuracy:Class 1.0
● Pulse output: Active energy pulse output
● Display: 8 digits display U, I, P, Q, PF, kWh and other energy consumption
● 3 keys to set parameters, such as code, address, baud rate, multi-tariff and communication protocol
● Rated voltage: AC 220V, 230V
● Rated current: 10(80)A, measure 0.01A-80A
● Standard&Certificate: MID, CE, IEC