AMC**L-AV3 Three Phase Voltage Meter
● Type: AMC48L-AV3,AMC72L-AV3,AMC96L-AV3
● AC current: AC100V,220V,380V
● 1 x RS485 with programmable Modbus RTU;
● Optional function: Alarm, Analog output, DI/DO and communication;
● Economic programmable meter;
● Accuracy: Class 0.5 -
ADF400 Series Multi-circuits Energy Meter
● Measure largest 36 circuits single-phase
or 12 circuits three-phase
● AC 3 * 220 / 380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm -
BA Series Intelligent Current Sensor
● Model: BA20(II)-AI,BA50(II)AI
● Aperture: 20mm,50mm
● Input: AC0-600A
● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
● Overload: 1.2 times of rated value
● Power supply: DC12V/DC24V -
AMC96L-E4/KC 3 Phase Panel Energy Meter
● Type: AMC96L-E4/KC
● Size: 96*96mm
● True RMS Measurements
● THD with 2-31st Harmonics
● Max/Min Log with Timestamp
● Internal Optional 4DI&2DO or 2DI&2DO&2AO
● Standard one Energy Pulse Output -
ADL3000-E/CT Three Phase Din Rail Energy Meter with 3 split CTs
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
AMC16MA Data Center Monitor Device
● Designed specifically for the power supply management of server in the data center
● Including 2 incoming line circuit and 36 outgoing line circuit
● U, I, P, Q, S, PF, kWh, kvarh
● Optional 2nd-15th harmonic
-
AKH-0.66I Series Current Transformer
● Current transformer for measurement
● Suitable for cables or busbar
● Used with energy meters or relays
● 30I, 40I Optional Din Rail Mounted
-
WHD Temperature & Humidity Controller
● Temperature and humidity measuring & controlling
● LED display
● Accuracy: Temperature ±1℃ Humidity ±5%RH
● Power supply: AC 85-265V, DC 100-350V -
4G Remote Wireless Smart Gateway
Working frequency bandLTE-FDD B1 B2 B3 B4 B5 B7 B8 B12 B13 B18 B19 B20 B25 B26 B28
LTE-TDD B38 B39 B40 B41
UMTS B1 B2 B4 B5 B6 B8 B19
GSM B2 B3 B5 B8 LORA 860~935MHz
-
Medical Isolation Power Supply Cabinet
● For distribution system in group 2 medical location● Using Q235A High Quality Cold Rolled Steel Plate● Louver type heat dissipation fan● Various installation types● IP31 -
AKH-0.66/K-36 Series Current Transformer For Cable
Current Transformer (CT) is used to transform the high AC(300-600A) current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.
-
ASG Series Signal Generator
● Generating Fault Location Signal ASG150● Detection of L1 and L2 disconnection● LED indicators: On, Comm, Test● CAN bus● Auxiliary power supply: DC24V -
AKH-0.66/K-24 Series Current Transformer For Cable
Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.
-
AIM-M100 Digital Remote Indicators for line isolation mornitoring
● AID150 Can monitor 1-16 AIM-M100● Remote monitoring● LED indicators:On, Insulation, Overload, Overtemp● Mute button● Test button● Auxiliary power supply: DC24V● RS485(MODBUS-RTU) -
Remote Alarm Indicators for Nursing Stations
● Remote monitoring● LED indicators:On, Insulation, Overload, Overtemp● Mute button● Test button● Auxiliary power supply: DC24V● RS485(MODBUS-RTU) -
AKH-0.66/K Split Core Current Transformer For Busbar
● Split core current transformer
● Easy to install without power off
● Suitable for electricity renovation project
-
Ground-fault detection and location relay
● Insulation fault location in AC IT systems
● AIL150-4: 4 measuring channels
● AIL150-8: 8 measuring channels
● LED indicators: On, Com
● CAN bus
● Auxiliary power supply: DC24V
-
Hospital Insulation Monitoring Relay
● Insulation monitoring for medical IT systems
● Load and temperature monitoring of isolation transformer
● Device disconnection monitoring
● LED indicators: On, Insulation, Overload, Over-temperature
● Alarm relay output
● Test button
● Insulation fault location
● 2 Way RS485 (MODBUS-RTU)
-
ACR10R-D**TE Single Phase Energy Meter With External Split CTs
● Type:ACR10R-D10TE,ACR10R-D16TE,ACR10R-D24TE,ACR10R-D36TE
● Current input:80A,120A,200A,300A
● Measurement current、voltage、active power, reactive power, power factor
● RS485 communication interface
● The interfaces with switch input and relay output
● LCD display -
AKH-0.66/Z Series integrated Current Transformer
● Combined current transformer is also called the three-phase current transformer.
● As current signal acquisition device, it is generally matched with multi-loop current monitoring device (AMC16), PZ300, moulded case circuit breaker and other products.
● It can save installation space, reduc the cumbersome wiring, be convenient to use and effectively reduce the cost.